Method 2 | Method 3 | Method 5 | Method 6 | Method 8A | Method 17 | Method 23 | Method 29| Method 201A/PM10
Boiler/ Combustion Services | Testing Services | Personel | Equipment | Testing Methods | Training | Safety | Quality | Pollutants
Services and Pricing | On-Site Testing | Quality | Guarantee
Process Consulting | Compliance Consulting | Permitting
Analyzers | Accessories | Gas Analyzers | CEM Equipment | Flow | Gas Conditioning | Heated Sample Lines | Sample Recovery | Source Sampling
On-Line Catalog | Used Equipment Sales USA | Used Equipment Sales Europe | MSDS Database | Credit Application | Rental Terms | Gas Cylinder Database
subglobal6 link | subglobal6 link | subglobal6 link | subglobal6 link | subglobal6 link | subglobal6 link | subglobal6 link
subglobal7 link | subglobal7 link | subglobal7 link | subglobal7 link | subglobal7 link | subglobal7 link | subglobal7 link
subglobal8 link | subglobal8 link | subglobal8 link | subglobal8 link | subglobal8 link | subglobal8 link | subglobal8 link

 

CleanAir Expresssmall logo

5 Channel Calibrator

The 5 Channel Calibrator is designed to interface CEM analyzers with five individual calibration gasses. The gasses can be controlled manually or remotely to flow through one of two calibration ports. Sub-Rack designed for installation into a standard 19" instrument rack. Flow-meter with stainless steel needle valve provides indication and control of calibration gas flow rate from 1 to 10 lpm. Auto Mode allows a data acquisition system equipped with a dry contact closure to control the calibration points remotely. A 12VDC output signal is provided for use by the control system via an Amphenol connector located on the rear of the 5 Channel Calibrator.

 

Stack Tester Comments :
We use the 5-Channel Calibrator to manage the FID cal gas to the probe tip in combination with the FLW-6 for all the other dry gas analyzers. The 5- Channel is also great when we are only running one or two analyzers or when we have many analyzers and don't need all the functions of the FLW-6.

The solenoid values require properly maintained gas cylinder pressure regulators to ensure the gas pressure to the solenoids never exceeds 40 psig. Pressure regulators which cannot control pressure with zero flow should not be used.


Features
Flow meter with stainless steel needle valve provides indication and control of calibration gas flow rate from 1 to 10 lpm.
AUTO Mode allows a data acquisition system equipped with a dry contact closure to control the calibration points remotely.
A 12 VDC output signal is provided for use by the control system via an Amphenol connector located on the rear of the calibrator. Sub-Rack Design for installation into a standard 19" instrument rack.


Part Number
0724

This item may also be rented through CleanAir Rentals