| To
Speak To A Customer Service Representative Call 800-223-3977 |
| Express
Catalog -->Ecom AC (Plus) Portable Stack Emissions Analyzer |
| Ecom
AC (Plus) |
Part
Number: 0703AC |
|
|
ECOM-SPLUS
Includes:
- 15
Foot Sample Line
- 1
Foot Pistol Grip Probe
- 1
Roll of Printer Paper
- 1
Package of Smoke Test Paper and Comparison Chart
-
1 CD ROM of the DAS Datalogging Software
-
1 RS232 Cable
-
2 Spare Sample Filters
-
1 Bottle of Spare NOx/SOx Filter Media
-
1 Manual w/Quickstart
-
Clean Air Instrument Rentals Shipping Carton
|
Specification
Notes:
- Detection
Method: Electrochemical Sensors.
-
Operating Temperature: Probe 30 °F - 1600 °F;
Instrument 20 °F - 122 °F.
-
Ranges:
| Parameter |
Range |
Accuracy |
| O2 |
0-21% |
2%
of Reading |
| CO |
0-4000
ppm |
5%
of Reading |
| NO |
0-4000
ppm |
5%
of Reading |
| SO2 |
0-4000
PPM |
5%
of Reading |
| NO2 |
0-500
PPM |
5%
of Reading |
| Draft |
0-40.00
in. H2O |
2%
of Reading |
| Ambient
Temperature |
0
- 250°F |
+/-
3 degrees |
| Stack
Temperature |
0
- 1600°F |
+/-
3 degrees |
- Inline
water traps and particulate filter.
-
Pump flow is 2-2.5LPM.
-
Data transfer is RS232 port from Ecom to computer.
-
Soot test capability.
-
Automatic and manual CO bypass system.
-
Automatic purge and zero calibration capability.
-
On-board printer for instant printouts of measurements.
(Also programmable for auto printouts at specified intervals)
| Power
Requirement: |
Voltage 110VAC/60HZ or Lead-Acid Rechargeable Battery
(Battery Life is 2-3 Hours) |
| Approx.
Shipping Weight: |
40
lbs |
Application
Notes:
- Suitable
for boiler flue gas analysis, engine emissions, and environmental
reporting of stack gas parameters.
- This
instrument is not intended for continuous emissions monitoring.
-
For high moisture applications, please inquire about the
Gamma gas conditioning unit for moisture removal.
|
Price:
Call For Pricing
USA List Price Only |
To