Clean Air Express Method 5 Heated Sampling Probes feature a unique sheathed design that allows quick and easy replacement of pitot, stack thermocouple, and liner. Geometric calibration of pitot is included: wind tunnel calibration is also an option.
Heated Sampling Probe Includes:
Heated Liner - 28/12 ball joint, 28/12 ball joint o-ring,
14/35 male taper or 5/8" chamfered end.
Liner material - (P) Pyrex (Q) Quartz (S) 316 stainless steel (I) Inconel (Titanium) Titanium
Type K probe liner thermocouple with standard male plug
Type K stack thermocouple with standard male plug
Type "S" pitot
Power Requirement: 120V AC or 220V configurations are available.
*Note: Standard probes use a flexible silicone heater (Max temp. 500 deg. F).Optional high temperature heaters are available.
*Note: Lengths below indicate effective length. To determine overall length, add 12". Custom probe lengths and materials are available. Please specify liner material when ordering
|
With 28/12 Ball Joint 5/8" Chamfered End Liner |
Part Number |
Liner Material |
Item |
0104-B- |
(P), (Q), (S), (I), (Titanium) |
4' M-5 Probe |
0106-B- |
(P), (Q), (S), (I), (Titanium) |
6' M-5 Probe |
0108-B- |
(P), (Q), (S), (I), (Titanium) |
8' M-5 Probe |
0110-B- |
(P), (Q), (S), (I), (Titanium) |
10' M-5 Probe |
With 28/12 Ball Joint/ 14/35 Male Tapered End Liner |
Part Number |
Liner Material |
Item |
0104-BT- |
(P), (Q), (S), (I), (Titanium) |
4' M-5 Probe |
0106-BT- |
(P), (Q), (S), (I), (Titanium) |
6' M-5 Probe |
0108-BT- |
(P), (Q), (S), (I), (Titanium) |
8' M-5 Probe |
0110-BT- |
(P), (Q), (S), (I), (Titanium) |
10' M-5 Probe |
With 28/12 Ball Joint O-Ring / 5/8" Chamfered End Liner |
Part Number |
Liner Material |
Item |
0104-BO- |
(P), (Q), (S), (I), (Titanium) |
4' M-5 Probe |
0106-BO- |
(P), (Q), (S), (I), (Titanium) |
6' M-5 Probe |
0108-BO- |
(P), (Q), (S), (I), (Titanium) |
8' M-5 Probe |
0110-BO- |
(P), (Q), (S), (I), (Titanium) |
10' M-5 Probe |
With 28/12" Ball Joint O-ring/ 14/35 Male Tapered End Liner |
Part Number |
Liner Material |
Item |
0104-BOT |
(P), (Q), (S), (I), (Titanium) |
4' M-5 Probe |
0106-BOT |
(P), (Q), (S), (I), (Titanium) |
6' M-5 Probe |
0108-BOT- |
(P), (Q), (S), (I), (Titanium) |
8' M-5 Probe |
0110-BOT- |
(P), (Q), (S), (I), (Titanium) |
10' M-5 Probe |
With 5/8" Chamfered End/ 14/35 Male Tapered End liner |
Part Number |
Liner Material |
Item |
0104-T- |
(P), (Q), (S), (I), (Titanium) |
4' M-5 Probe |
0106-T- |
(P), (Q), (S), (I), (Titanium) |
6' M-5 Probe |
0108-T- |
(P), (Q), (S), (I), (Titanium) |
8' M-5 Probe |
0110-T- |
(P), (Q), (S), (I), (Titanium) |
10' M-5 Probe |
This item may also be rented through CleanAir Rentals
|
|