3-D
Flow Certification
Certification
Testing
QA/QC and Monitoring Plans
System
Specification and Design
Temporary
Systems
|
|
|
CEMS Services
RATA Testing, 3-D Flow Certification
From initial design and specification to QA/QC planning,
certification tests and EDR reporting or even installing and operating temporary
systems, CleanAirs team of professionals are ready to assist you with
your continuous emissions monitoring requirements. CleanAir provides a full
range of services to all types of industries as follows:
System
Specification and Design
Specification Writing
Development of detailed system specifications which can be used to issue Bid
Requests.
Proposal Evaluation and Review
Evaluation of vendor bids for responsiveness, accuracy, technical competence
and cost effectiveness.
Supervision of System Installation
- Selection of sampling
locations
- Pre-installation
equipment check
- Insure vendor
follows design specification during installation
Certification
(RATA) Testing
Performance of all certification tests as required by state or federal regulations.
These could include:
- Zero and calibration
drift test
- Cylinder gas audits
- Relative accuracy
test (40CFR 60 and 75)
- Bias check
- Quarterly and
annual QA/QC audits
3-D
Flow Studies
Our experience indicates the 3D traverse can measure flow rates up to 15% lower
than that of the S-type pitot traverses. To minimize the disparities between
the flow rates measured at the stack with EPA Method 2 test procedures (S-type
pitot tube) and the calculated flow rate from combustion inputs, CleanAir provides
the following 3-D flow testing services:
- 3-D volumetric
flow determination (EPA Methods 2F and 2G)
- Wall effect determinations
by EPA Method 2H
- Wind tunnel calibration
services
- 3-D probe and
electronic manometer console manufacturing and rental
QA/QC
and Monitoring Planning and Implementation
Regulatory Review
This is done to determine the QA/QC requirements applicable to the
source under state and federal regulations. These may include the requirements
of 40CFR Part 60, Appendix F or 40CFR Part 75, Appendices A and B.
Development of QA/QC Plans
A step-by-step written plan is developed for each instrument and for the
system as a whole. This plan is specific for the instruments involved and for
the plant site. The plan includes at a minimum the following procedures:
- Calibration error
test
- Calibration adjustment
- Preventative maintenance
- Audits
- Recordkeeping
and reporting
QA/QC Implementation
QA/QC plans require periodic audits and reports to state and federal pollution
control agencies. Services provided are:
- Quarterly or semi-annual
audits
- Annual certification
testing
- Assistance with
state and federal agency paperwork
- Operator certification
and training
|




|
|