Determination
of Particulate and Gaseous Mercury Emissions from Sewage Sludge Incinerators
– USEPA Method 101A
USEPA Method 101A is used for the determination of mercury (Hg) emissions
from sewage sludge incinerators and other sources as specified in
an applicable subpart of the regulations.
Particulate and gaseous Hg emissions are withdrawn isokinetically
from the source and are collected in acidic potassium permanganate
(KMnO4) solution. The Hg collected (in the mercuric
form) is reduced to elemental Hg, which is then aerated from the solution
into an optical cell and measured by cold vapor atomic absorption
spectrophotometry.
Excessive oxidizable organic matter in the stack gas prematurely depletes
the KMnO4 solution and thereby prevents further collection
of Hg.
To