From initial design and specification to QA/QC planning, certification tests and EDR reporting or even installing and operating temporary systems, CleanAir’s team of professionals are ready to assist you with your continuous emissions monitoring requirements. CleanAir provides a full range of services to all types of industries as follows:
System Specification and Design
Specification Writing
Development of detailed system specifications which can be used to issue Bid Requests.
Proposal Evaluation and Review
Evaluation of vendor bids for responsiveness, accuracy, technical competence and cost effectiveness.
Supervision of System Installation
Certification (RATA) Testing
Performance of all certification tests as required by state or federal regulations. These could include:
3-D Flow Studies
Our experience indicates the 3D traverse can measure flow rates up to 15% lower than that of the S-type pitot traverses. To minimize thedisparities between the flow rates measured at the stack with EPA Method 2 test procedures (S-type pitot tube) and the calculated flow rate from combustion inputs, CleanAir provides the following 3-D flow testing services:
3-D volumetric flow determination (EPA Methods 2F and 2G)QA/QC and Monitoring Planning and Implementation
Regulatory Review
This is done to determine the QA/QC requirements applicable to the source under state and federal regulations. These may include the requirements of 40CFR Part 60, Appendix F or 40CFR Part 75, Appendices A and B.
Development of QA/QC Plans
A step-by-step written plan is developed for each instrument and for the system as a whole. This plan is specific for the instruments involved and for the plant site. The plan includes at a minimum the following procedures:
QA/QC Implementation
QA/QC plans require periodic audits and reports to state and federal pollution control agencies. Services provided are:
To Speak To A Sales Representative Call 800-208-6162