CleanAir SO3 Controlled Condensation System

CleanAir SO3 Controlled Condensation System

$11,628.95$12,930.46

SKU:
SO3 CCS-

SO3 Controlled Condensation System

SO3 Controlled Condensation SystemThe CleanAir SO3 Controlled Condensation System is designed to allow the separation of H2SO4 from SO2 by cooling the gas stream below the dew point of H2SO4 but above the H2O dew point. Applicable for SO3 Determination of Sulfuric Acid Vapor or Mist (including Sulfur Trioxide) and Sulfur Dioxide Emissions from Kraft Recovery Furnaces. The condenser utilizes a straight quartz tube filled with quartz wool surrounded by a temperature regulated water bath. No recirculation pump or external water heaters are required. The system works in conjunction with standard Method 5 Isokinetic Control Consoles and Heater Controllers. For more information on this method, please visit the EPA’s CFR 40 website.

*Note: Train Purchase Online can only be purchased in the United States.  If ordering outside the United States please contact us by phone at (847)-654-4606 or email us at: express@cleanair.com.

Qty
Part Number
SO3 Probes and Liners

1 Probe

1 Liner

Spare Liners

Recommended

4 ft. Stainless Steel Heated Probe (600 °F) with 4 ft. Quartz Liner
6 ft. Stainless Steel Heated Probe (600 °F) with 6 ft. Quartz Liner
8 ft. Stainless Steel Heated Probe (600 °F) with 8 ft. Quartz Liner
4 ft. Stainless Steel Heated Probe (600 °F) with Cable Heater, No Liner
6 ft. Stainless Steel Heated Probe (600 °F) with Cable Heater, No Liner
8 ft. Stainless Steel Heated Probe (600 °F) with Cable Heater, No Liner
4 ft. Quartz Glass Probe Liner 18/9 Ball Joint
6 ft. Quartz Glass Probe Liner 18/9 Ball Joint
8 ft. Quartz Glass Probe Liner 18/9 Ball Joint
Qty
Part Number
SO3 Sample Train Glassware and Connectors
1
Quartz 90° Connector 18/9 Ball & Socket Joint
1
Quartz Glass Filter Holder 18/9 Ball & Socket Joint

1 Water Bath

1 Condenser Tube

Temperature Regulated Water Bath (150 °F) with Quartz Glass Condenser Tube
Temperature Regulated Water Bath (150 °F) No Condenser Tube
Quartz Glass Condenser Tube 18/9 Socket Joint
2
Filter Holder Springs
1
37mm Quartz Filter Media 100/pk
3
18/9 Glassware Clamps
1
Quartz Glass Wool
1
18/9 Ball Joint Plug (for leak checking)
1
18/9 Ball Joint to ¼” Hose Barb
1
Purge Pump Assembly
1
1/2″x3/8″ PTFE Reducing Union
10 ft.
3/8″ PTFE Tubing
1
28/12 Socket to ¼” Hose Barb
4
Impinger with Modified Stem (straight)
4
180° Connector 28/12 Socket
Qty
Part Number
SO3 Hardware
1
SO3 Heated Filter Box (550 °F)
1
Universal Temperature Controller
1
Method 5 Control Console and Pump
1
4 Impinger Compartment
1
28/12 Impinger Outlet
1
15 ft. SO3 Electrical Umbilical
1
50 ft. SO3 Electrical Umbilical
15 ft. SO3 Sample Umbilical
1
50 ft. SO3 Sample Umbilical

No additional documents available for this product